1. Connect the Floor Stapler to the air hose and turn on the air compressor.
Note: Before using on a floor, test the unit on a scrap piece of wood. Adjust the driving depth
by providing more or less air pressure. Never exceed 125 PSI.
Warning! Keep your feet clear of the Stapler. Refer to Figure 2.
2. Hold the Handle (44) securely with one hand and grip the Hammer with the other
hand.
FIGURE 3
3.
Fasteners exit the Stapler from the bottom in the
direction indicated above.
Hammer
Face (1)
(Striking this with the
Trigger (33) held causes
the stapler to fire.)
Trigger (33)
(This helps prevent
unintentional firing.)
FIGURE 2
Make sure the Base Plate (52) is over the Fastener target position. Press down hard
so that the Base Plate (52) is firmly contacting the floor. Then squeeze the Trigger (33)
and strike the Hammer Face (1) with the Hammer to drive out a Fastener. Lift the tool
off of the floor. See Figure 3.
4. Repeat the process until you are finished. Then, disconnect the Floor Stapler from the
air source.
Warning! After disconnecting the Stapler from the air compressor, there could still be enough
air pressure to fire the Stapler. After the air compressor hose is disconnected, always
fire the Stapler into a piece of scrap to make sure all of the air is expended.