Page 12For technical questions, please call 1-800-444-3353.SKU 92359
(64). Make sure the Latch closes
securely. If it does not engage, the
nail head is not in the slot in the
upper portion of the Feed Hook (50).
6. To adjust the Shingle Gauge: The
Bracket (79) controls roof shingle
spacing. To adjust the Bracket
to work with a particular width of
shingles, use the accessory Hex
Wrench to loosen the Screw (80) on
the Bracket. Slide the Bracket to the
desired spacing. Then, retighten the
Screw. See graphic, below.
General Operating Instructions
1. Before each use, test the Tool as
directed in the prior section.
2. If an automatic oiler is not used, add
a few drops of Pneumatic Tool Oil into
the tool’s airline connection before
use. Add a few drops more after
each hour of continual use.
3. Attach the Nailer to the air
supply at the Air Inlet (93). Start
your compressor and check the
pressure making sure it is set at the
recommended 65-90 PSI and do not
exceed 90 PSI.
4. To re, place the nose of the Nailer
on the workpiece and push down until
it stops. Pull the Trigger to re one
nail. Note: The Nailer should not
re if the Nose is not fully depressed.
To re another nail, lift the Nose of
the Nailer off the workpiece, which
will feed another nail into the ring
chamber. Repeat previous step
to re. Avoid forcing the nose in
an angle. Do not re nails on
top of each another or into any
hard object. Nails could bounce
off, damaging the workpiece or
causing PERSONAL INJURY. See
graphic, below.
5. Do not press the Nose of the Roong
Nailer against the work surface with
excess force. Allow the tool to do the
work. Always allow the tool to recoil
off the workpiece.
6. Caution: While working on roofs,
tar and dirt may build up on the
Nose of the Roong Nailer. This can
prevent normal operation. Remove
buildup with a nonammable solvent.
NEVER use gasoline or other
ammable solvents. Do not immerse
Roong Nailer in an approved solvent
beyond the height of the nail heads,
to avoid getting the solvent into the
BOTTOM VIEW
Screw
(80)
Bracket
(79)
SHINGLE SPACING
Air Supply Hose
(Not Included)
Trigger
(47)
Nose
Roong Shingle

Related product manuals