Service Manual
VMH 9/12/18/24 SU Series
VMH 30/36 SD Series
Inverter Single Zone
Ductless Mini-Split
www.marsdelivers.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Century A-VMH18SU-1 and is the answer not in the manual?

Summary

1. Precautionary Measures

1.1 Safety Precautions

General safety guidelines to prevent injury and property damage during operation and servicing.

1.2 Installation and Operational Warnings

Critical warnings regarding installation, electrical safety, and handling of the unit.

Installation Cautions

Important cautions regarding refrigerant leakage, drainage, and leveling for proper installation.

6. Installation Details

6.1 Wrench Torque Sheet for Installation

Table specifying torque values for various pipe connection diameters during installation.

6.4 Initial Installation Procedure

Steps for initial installation, including leak testing, evacuation, and vacuum pump procedures.

Refrigerant Charging Procedure

Detailed procedure for charging the system with refrigerant, including weight and pressure checks.

8. Electronic Function

8.3.1 Compressor Restart Delay Protection

Delay mechanism to protect the compressor from frequent start-ups and restarts.

8.3.2 Compressor Top Temperature Protection

Protection against overheating at the compressor top, causing the unit to stop.

9. Troubleshooting Guide

Troubleshooting Safety Precautions

Crucial safety warning about discharging electricity from capacitors before servicing.

9.1 Indoor Unit Error Display Codes

Table listing indoor unit error codes, their meanings, and corresponding LED/display statuses.

9.2 Outdoor Unit Error Display Codes

Table showing outdoor unit error codes, problems, and LED indications (Green/Red).

9.3.1 EEPROM Parameter Error Diagnosis

Diagnostic steps and solutions for EEPROM parameter errors (E0/F4).

9.3.2 Communication Error Diagnosis (E1)

Troubleshooting guide for communication errors between indoor and outdoor units (E1).

9.3.3 Zero Crossing Detection Error Diagnosis

Diagnostic steps and solutions for zero crossing detection errors (E2).

9.3.4 Fan Speed Out of Control Diagnosis

Troubleshooting for indoor fan speed control issues (E3/F5).

9.3.5 Temperature Sensor Error Diagnosis

Diagnosis and solutions for temperature sensor errors (E4/E5/F1/F2/F3).

9.3.6 Refrigerant Leakage Detection Diagnosis

Troubleshooting steps for refrigerant leakage detection (EC).

9.3.7 Overload Current Protection Diagnosis

Diagnostic steps and solutions for overload current protection (F0).

9.3.8 IPM Malfunction or IGBT Over-Current Protection Diagnosis

Troubleshooting for IPM malfunction or IGBT over-current protection (P0).

9.3.9 Over Voltage or Low Voltage Protection Diagnosis

Diagnosis and solutions for over/under voltage protection (P1).

9.3.10 IPM Module High Temperature Protection Diagnosis

Troubleshooting for high temperature protection of the IPM module (P2).

9.3.11 Inverter Compressor Drive Error Diagnosis

Diagnostic steps and solutions for inverter compressor drive errors (P4).

9.3.12 Low Pressure Protection Diagnosis

Troubleshooting for low pressure protection issues (P6).

Main Parts Check

10. Disassembly Instructions

Century A-VMH18SU-1 Specifications

General IconGeneral
BrandCentury
ModelA-VMH18SU-1
CategoryAir Conditioner
LanguageEnglish