35
COLD WEATHER OPERATION
The waste gate controller will not respond quickly to variations in manifold pressure when oil
temperature is near the lower limit of the green arc. Therefore, under these conditions, throttle
motion should be made slowly and care should be exercised to prevent exceeding the 32” Hg
manifold pressure limit. In addition, the fuel flow indications may exceed 24 GPH on takeoff if the
mixture is not leaned to compensate
Winterization kit is not required