VERTICAL MOUNTING
Rotate the keypad for vertical mounting:
1 Disconnect all plugs from the main
circuit board. Remove board (See
control board connections below).
2 Remove bracket (4 screws).
3 Rotate keypad 90° clockwise. Bracket
notch lines up with ribbon cable on
the keypad.
4 Reverse the sequence to reassemble
the unit.
5 Reconnect all plugs to the control
board.
Main Circuit
Board
Bracket
Keypad
1
2
3
1-5/8 in. Conduit Hole
Knockouts for 5/16 in.
Knockouts for 3/8 in.
15 in.
3-1/16 in.
9 in.
1-5/8 in.
1-15/16 in.
2 in.
12 in.
7 in.
9-1/2 in.
6 in.
3-1/16 in.
1-1/2 in.
1/2 in.
Installation
6 in.
3-15/16 in.
3-1/16 in.
10-1/4 in.
3-1/16 in.
5-1/8 in.
Mounting Holes (4)
for 5/16 in.
1-1/16 in.
Conduit Hole
3 in.
EL25 & EL2000
TELEPHONE ENTRY/ACCESS CONTROL SYSTEM
Mount to a wall or pedestal. Knock out
the desired mounting plugs using punch.
J201 MIC
J402 LED
J402 SPKR
J402 LED
J406 LCD
J401 KEYPAD
PEDESTAL
WALL
Knockouts
for 3/8 in.
Knockouts
for 5/16 in.
PEDESTAL
WALL
Mount to a wall or pedestal.
The EL25 is for surface mount applications only.
Unlock the unit and open cover. Carefully lift
mounting plate up then slide out on hinges.
The EL2000 is for surface and recessed mount only.
Apply pressure to the right-side of the unit. While
maintaining pressure, turn key clockwise and open
the cover.
Unplug the two main harnesses.
Line up notch with screw and push hinge out. Remove
the mounting plate from the cover.
EL2000 EL2000
EL25 EL25
OPTIONAL
Slide cover out of hinges to remove.
(Optional)
1 1
2
Unplug the two main harnesses.
(Optional)
2
3 3
Turn the key counter-clockwise to
the locked position. Close the cover.
Apply pressure to left-side until
you hear a “click” sound. Apply
pressure to right-side of unit until
you hear a “click” sound.
5 5
4 4
EL25
EL2000
Optional modules let you expand the system to fi t your
specifi c needs. The Wiegand output module lets you add
card readers and/or remote keypads. Our RF module
provides convenient access through gates or doors
with Passport™ transmitters. Plus, the system is now
designed to automatically detect the addition and location
of each new plug-in module, making installation and
programming faster and easier than ever before.
These instructions are for general installation and setup.
For more information including detailed wiring specs,
download the guide at www.liftmaster.com.
RESIDENTIAL AND COMMERCIAL
TELEPHONE ENTRY SYSTEMS WITH EXPANDED
CAPACITY AND ENHANCED VERSATILITY
Lock the unit. Do not pinch wires
when closing and locking the unit.
Normally Open
Common
Use 18-24 AWG
Normally Open
Siemens S10K30 MOV
(Metal Oxide Varistor)
or equivalent.
Common
Use 18-22 AWG
1N4005 diode
or equivalent.
AC or DC Power for
Door Strike (Not Provided)
Normally Closed
Siemens S10K30 MOV
(Metal Oxide Varistor)
or equivalent.
Common
Use 18-22 AWG
1N4005 diode
or equivalent.
AC or DC Power for
Door Strike (Not Provided)
Home Phone
Bypass Board
for Unit 1
Ring Ring
RingTipTip
Tip
Bypass Board
for Unit 2
Home Phone
Unit ID 2
Output Board
Telco Entrance Box
Demarcation Point
Alarm SystemPosition
(Not Provided)
Sentex Ovation Unit
Telco Entrance Box
Demarcation Point
Ring
Tip
Ring
Tip
Internal Phone System Analog Trunk
Green Ground Wire
Earth Ground Rod
12 ft Maximum
Ground Wire
Metallic Cold
Water Pipe
Electrical Panel
Output Board
CONNECTING TO THE TELCO LINE
The bypass board allows the unit(s) to be disconnected without interrupting
normal telephone operation. If the unit(s) will be used in conjunction with an
alarm system, you must connect the telephone line to the alarm system fi rst.
If the units are not connected in this order, they will not operate properly.
Up to 7 units can share the same phone line. You must program the unit id’s
for each unit wired in the series. See Keypad Programming manual.
The bypass board (located inside the property) allows access to the phone in
case the unit(s) fail.
NOTE: Installation where fi ber optic phone lines are present may require
additional modifi cations from your telephone provider. Contact your provider
for more information.
• When a unit is in use, the bypass switch must be set to the
operate position.
• When a unit is disconnected, the bypass switch must be set to the
bypass position.
14-Pin to
Control Board
Ring
Ring
Tip
Tip
• To AVOID damaging gas, power or other underground utility
lines, contact underground utility locating companies BEFORE
digging more than 18 inches (46 cm) deep.
• Contact the building inspector’s offi ce in the municipality where
you plan to install the unit for correct grounding materials and
installation procedures.
• Ensure that the system is grounded properly. The units contain
a number of static sensitive components that can be damaged
by static discharge.
• DO NOT ground the units to a pedestal post (gooseneck) if one
is used.
GROUND THE UNIT
Install an earth ground rod no further than 12 feet from the unit and
use a minimum of 12 gauge wire in most cases. The type and length
of earth ground rods vary by region.
NOTE: Keep ground wire as straight as possible.
ALTERNATIVE GROUNDING SOLUTIONS
The unit may be grounded to a metallic or an existing electrical system
within 12' of the unit.
CONNECTING TO A DEDICATED TELCO LINE
Installation where fi ber optic phone lines are present may
require additional modifi cations from your telephone
provider. Contact your provider for more information.
Up to 7 units may be installed. You must program the
unit id’s for each unit wired in the series.
See Keypad Programming manual.
To next unit
(Unit ID 5 then Unit ID 4 etc.)
Unit ID 2
Alternative Grounding Solutions
CONNECTING TO AN INTERNAL PHONE SYSTEM
The units can be wired to any analog trunk in an internal home phone
system.
Installation where fi ber optic phone lines are present may require
additional modifi cations from your telephone provider. Contact your
provider for more information.
Up to 7 units may be installed. You must program the unit id’s for each
unit wired in the series. See Keypad Programming manual.
CONNECTING TO AN NPBI SYSTEM
Up to 7 units may be installed. You must program
the unit id's for each unit wired in the series.
See Keypad Programming manual.
Disconnect power at the fuse box BEFORE proceeding. The unit
MUST be properly grounded and connected in accordance with
national and local electrical codes. NOTE: The unit should be on a
separate fused line of adequate capacity.
• A static discharge can damage circuit boards
• NEVER run telco wires and high voltage wires in the same
conduit. The high voltage may interfere with the telco wires,
possibly causing the system to malfunction.
OR
Wiring
CONNECTING A GATE OPERATOR
Refer to the gate operator manual for proper relay
strike time. Additional opening or exit devices can
be connected to any of the 4 relays.
CONNECTING A MAGLOCK
The maglock can be connected to any of the 4 relays.
FOR AC POWER: Install a Siemens S10K30 MOV (Metal Oxide Varistor)
or equivalent
FOR DC POWER: Install a 1N4005 diode or equivalent.
DO NOT USE THE UNIT’S POWER SUPPLY FOR THE MAGLOCK.
CONNECTING TO A DOOR STRIKE LOCK
The door strike can be connected to any of the 4 relays.
FOR AC POWER: Install a Siemens S10K30 MOV (Metal Oxide Varistor) or equivalent.
FOR DC POWER: Install a 1N4005 diode or equivalent.
DO NOT USE THE UNIT’S POWER SUPPLY FOR THE DOOR STRIKE.
STAND ALONE SYSTEM
The unit can be a stand alone system that allows communication between
the unit and a resident’s phone. Connect a twisted wire (18-24 AWG) from
the RES terminal block on the unit's output board, to the resident's phone.
Up to 7 units can share the same phone line. You must program the unit id’s
for each unit wired in the series. See Keypad Programming manual.
Only disable the Telco mode of the unit farthest away from the house. See
“Disable Telco Mode” in the Keypad Programming manual.
NOTE: Ringer Equivalence Number (REN) of “5” maximum.
To next unit
(Unit ID 3, then Unit ID 4, etc.)
TERMINAL BLOCK CONNECTIONS
Resident - Tip/Ring
Telco - Tip/Ring
Relay 4, NO, NC, COM
Relay 3, NO, NC, COM
Relay 2, NO, NC, COM
Relay 1, NO, NC, COM
DO NOT overload the
removable terminal
block connectors.
One wire per hole.
1
2
3
4
5
6
Unit ID 6
For additional
units
For additional
units
To TELCOTo RES
Use 18-24 AWG
2 twisted pair