201319 - 4500W DUAL FUEL ELECTRIC START INVERTER GENERATOR
OPERATION
26
4. Press and hold the yellow ignition switch on the EZ Start Dial
toward the center of the dial. Release as the engine begins to
start. If the engine fails to start within five seconds, release
the switch and wait at least ten seconds before attempting to
start the engine again.
CAUTION
If the ignition switch is held down in the “START” position
longer than 5 seconds it could damage the starter.
NOTICE
If the engine is cranked longer than 5 seconds, the engine can
flood and will not start.
NOTICE
If the engine starts but does not continue to run, make certain
that the generator is on a flat, level surface. The engine is
equipped with a low oil sensor that will prevent the engine
from running when the oil level falls below a critical threshold.
Manual Start
Cold Engine Start
5. Move the EZ Start dial to the “CHOKE” position.
6. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.
7. Do not over-choke. As soon as engine starts, turn the EZ
Start dial to the “RUN” position.
Warm Engine Start
3. Move the EZ Start dial to the “RUN” position.
4. Pull the recoil cord slowly until resistance is felt and then pull
rapidly.