QuickQ Console Testing
ChamSys Ltd – Rev 1.0 July 2021
The LCD Test Cards are used during initial console QC and not required for this test. If
you do select this test, tapping on the touch screen advances through each test card.
Menu Tests are now complete – Select, Back → Start QuickQ
Wi-Fi Tests
1. Press ‘Wi-Fi’ icon on top right of display (next to the record button) to display
the consoles QR code, ensure status is set to enabled here if QR does not
display.
2. Open QuickQ Remote app on Android/iOS phone/tablet, select QR code from the
options
3. Scan QR code on console with phone/tablet
4. Verify that phone/tablet has connected to the console, this proves Wi-Fi on the
console is working correctly.
Network Tests
1. Connect a network node (e.g. SnakeSys B4 or any Artnet node) to the console via
standard network cable (cat5e or cat6).
2. Go to Menu (☰) → Settings → Network → Wired. Confirm IP Address on the
QuickQ is in the range IP Scheme as the node. For example if using a SnakeSys
node these use a 2.x.x.x IP on a 255.0.0.0 subnet.
3. Go to Menu (☰) → Settings → DMX Settings. For Universe 1, set the ‘send over
network’ option to Artnet, ArtNet Universe to 0 and Slide on the ‘Test Mode’
option. This will ramp all channels on this universe.
4. Configure your network node to receive Artnet universe 1 and prove Data is
received by the node (usually by an LED next to the DMX port on the node).
5. Switch off ‘test mode’ in the DMX settings on the QuickQ console.