7
R
- As supplied by the factory the appliance is set up with the domestic hot water function always
enabled and the domestic hot water programming function disabled.
The instructions for enabling this program are given in chapter 15, which is addressed specifically
to installers (parameter H91).
If the program is enabled program lines from 31 to 36 must be set up as described in heading 3-
5.1.
- press either of the
keys to access the programming function;
- press these keys until the display shows P5, referring to the temperature to be set;
- press the
keys to set the temperature required.
This operating mode is enabled when minimum temperature central heating mode
is activated
or when the daily central heating program does not require heat
.
N.b – With the outdoor sensor probe connected, parameter P5 can be used to set the minimum
room temperature in the premises to be heated.
Range
0…23:59
25..80
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
0...1
Factory
setting
———-
25
6:00
22:00
0:00
0:00
0:00
0:00
0:00
24:00
0:00
0:00
0:00
0:00
0
Parameter description
Time of day setting
Minimum central heating temperature setting (°C)
Start of first daily period of automatic central heating
End of first daily period of automatic central heating
Start of second daily period of automatic central heating
End of second daily period of automatic central heating
Start of third daily period of automatic heating
End of third daily period of automatic central heating
Start of first daily period of domestic hot water production (*)
End of first daily period of domestic hot water production (*)
Start of second daily period of domestic hot water production (*)
End of second daily period of domestic hot water production (*)
Start of third daily period of domestic hot water production (*)
Fine End of third daily period of domestic hot water production (*)
Reset of daily central heating and domestic hot water production programs (factory
settings). Press the - + keys together for about 3 seconds; the number 1 appears on
the display. Confirm by pressing either of the
keys
Parameter
N.
P1
P5
P11
P12
P13
P14
P15
P16
P31
P32
P33
P34
P35
P36
P45
3.7 Table of user-settable para-
meters
Note: Parameters from P31 to P36 can be displayed only if the domestic hot water program has been
enabled as described in chapter 15 for the attention of the installer (parameter H91).
3.5.2 Setting the daily
times for domestic
hot water mode
operation
3.6 Setting the minimum
central heating tempe-
rature