20Réf. : CH - 1254 - I - 0 - EN
Does the pilot burner
flame light ?
Does the spark continue
for 25 seconds?
Is the flame failure neon
illuminated?
Press reset button
Is there 230V at L & N
connections on the neon?
Replace the neon
Is there 20mb pressure at
Gas Valve inlet?
Check & rectify supply
Is there gas at the pilot
feed tapping on the Valve?
Remove Burner Ignition
Control from valve
Is resistance across pilot
solenoid connections V1
4.3 kohm ±10%?
If not, replace gas valve
Is the Pilot Feed Pipe or
Pilot Burner Injector
blocked?
If so, clean or replace
Do the main burners light ?
Is there 20mb pressure at
Gas Valve inlet?
Check & rectify supply
Is there gas at the burner
pressure test point?
Remove Burner Ignition
Control from valve
Is resistance across main
solenoid connections V2
3.9 kohm ±10%?
If not, replace gas valve
Remove cover from
Burner Ignition Control
Is there 230V across pins
10 & 11 of edge connector?
Check boiler internal wiring
Does the boiler shut down
when the flow
temperature reaches 85°?
BOILER
OPERATING
CORRECTLY
Ensure control knob is fully
clockwise and the
thermostat phial is correctly
fitted in the pocket
Replace Temperature
Control Thermostat
Check and adjust the
burner pressure to that
stated in Technical Data
Replace gas valve
Replace Burner Ignition
Control
NO
YES
YES
NO
YES
NO
YES
NO
YES
NOYES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
Pilot Solenoid Connections
Main Solenoid Connections