27
BOILER IGNITION (fig. 9)
To switch the boilers on, follow the pro-
cedure below:
- Press and rotate the control knob
of the gas valve in pilot position (A)
- Keep the knob pressed for a few
seconds and simultaneously and
repeatedly activate the piezoelectric
activator button (2).
- Release the button, ensuring that
the pilot burner remains on. Should
it switch off, repeat the operation.
- To switch the main burner on, press
and rotate the control knob to the
ON position (B).
ADJUSTMENT OF HEATING
TEMPERATURE (fig. 10)
The heating temperature can be adju-
sted with the stat knob with a range
from 45ºC to 85ºC (1).
The temperature setting can be
checked on the thermometer (2).
For an always optimum operation of
the boiler we recommend not to redu-
ce the operating temperature below
60ºC.
SWITCHING OFF THE BOILER (fig. 9)
To switch the boiler off, press and
rotate the control knob of the gas
valve to position OFF (C).
Close the gas pipe cock if you are not
going to use the boiler for a long time.
SAFETY STAT (fig. 9)
EDENA EVOLUTION EF models are
equipped with safety stat
(3)
with
manual resetting.
In case the boiler
temperature exceeds 95°C the
WARNINGS
– In case of fault and/or incorrect equipment operation, deactivate it, without making any repairs or taking any direct
action. Contact the nearest authorised technical personel.
– The installation of the boiler and any servicing or maintenance job must be carried out by qualified personnel. Under
no circumstances, the devices sealed by the manufacturer can be tampered with.
– It is absolutely prohibited to block the intake grilles and the aeration opening of the room where the equipment is
installed.
USER INSTRUCTIONS
LIGHTING AND OPERATION
FR
ENG