Display | LCD |
---|---|
Series | LEGEND |
Manufacturer | Chattanooga |
Application | Pain management, muscle rehabilitation |
Frequency Range | 1-150 Hz |
Pulse Width | 50-400 microseconds |
Waveforms | TENS |
Battery Type | rechargeable |
Provides details on the performance, quality, and features of the Intelect Legend Series Stim system.
Explains symbols and definitions for safety instructions like CAUTION, DANGER, and Dangerous Voltage.
Details safety precautions, including not using sharp objects, operating conditions, and avoiding liquids.
Lists warnings related to device restrictions, grounding, electromagnetic interference, and user responsibilities.
Highlights dangers, including risks with implanted neurostimulation devices and incorrect voltage usage.
Details indications, contraindications, and adverse effects for electrical stimulation therapy.
Outlines indications, contraindications, and warnings for Interferential and Premodulated stimulation modes.
Details precautions for skin irritation and notes patient selection importance for treatment effectiveness.
Lists indications and contraindications for Russian and High Volt stimulation modes.
Details warnings about long-term effects, pregnancy, heart problems, epilepsy, carotid sinus, and transthoracic application.
Advises precautions for recent surgery, sensory nerve damage, and tendency to hemorrhage.
Notes potential skin irritation or hypersensitivity and reports skin irritation and burns from stimulation.
Describes the operator interface components like LCD and LEDs for the 2S and 4S models.
Details the function of Start, Stop, and Pause buttons, and channel selection for operation.
Details carrier frequency, beat frequency, scan time, amplitude, and voltage for Interferential and Premodulated modes.
Lists parameters for Russian and High Volt modes, including frequency, duty cycle, amplitude, and output current.
Guides on unpacking, inspecting for damage, and connecting the unit to a power outlet.
Lists standard accessories included with the Intelect Legend Series Stim 2S and 4S models.
Explains pain management therapy using Interferential and Premodulated waveforms, and their parameters.
Details the Interferential waveform, electrode positioning, channel selection, and amplitude modulation.
Explains Beat Frequency options (Variable, Fixed) and Amplitude Modulation (Scan Percentage) for Interferential mode.
Details how to select Variable and Fixed frequencies for Beat Frequency in Interferential mode.
Describes the Premodulated waveform, Cycle Time, Beat Frequency options (Variable, Fixed).
Covers muscle contraction waveforms (High Volt, Russian) and High Volt parameters like Method, Polarity, Cycle Time.
Explains High Volt Sweep options (Continuous, Hz ranges) and Frequency adjustment.
Details High Volt Ramp time options and Display modes (Voltage, Peak Current).
Details Russian waveform parameters: Mode, Cycle Time, Burst Frequency, Ramp, and Duty Cycle.
Instructions for changing saved presets and adjusting the LCD screen contrast.
Explains the use of the optional High Volt probe for manual stimulation delivery.
Instructions for cleaning the unit and patient applied parts using damp cloths and germicides.
Details authorized personnel for repairs, recalibration recommendations, and monthly checks.