Replacing Fuses
If the unit does not function at all when connected to the main power supply i.e. does not illuminate
after replacing the lamp. Then it is highly likely that the fuse has blown.
Disconnect from main power supply before attempting to replace either lamps or fuse.
In order to replace the fuse, disconnect from the main power supply first, and then unscrew the
fuseholder cover to reveal the fuse. The unit has a label attached which indicates the correct fuse
rating and you will also find this listed as part of the specifications for the unit later in this guide. It is
most important that replacement fuses are of the correct rating. Failure to use the correct fuse could
damage the lighting effect beyond economic repair.
The fuse should simply be placed inside the holder and the screw cap replaced, when this is done
connect to the main power supply to check. If the unit is still not working then please CHAUVET for
servicing.
Caution
Do not touch unit or lamps while hot.
No user serviceable parts inside, please refer to CHAUVET for service.
Power Connections
The unit is supplied with a power plug appropriate to its voltage and destination. Should any other
connections be required they must be carried out with the following configuration.
Earth = Green/Yellow cable
Neutral = Blue cable
Live = Brown cable
In the USA & Europe, it is required that all plugs are 3-pin type i.e. with Earth/Ground connection.
In the UK, it is required that all mains plugs are fitted with 5A fuses.
Packing List
Please check contents of your packaging carefully for the following items:
1 x CH-214 Tetra (Master Head)
3 x CH-214 Tetra (Linkable Heads)
4 x 64514 / 64516 Lamps
3 x 3m (10’) linking cables
1 x Literature – user guide / warranty card