EasyManua.ls Logo

Chauvet LED PAR 38-18B - User Manual

Chauvet LED PAR 38-18B
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
3000 N 29
th
Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
LED PAR 38-18B
LED PAR 38-18C
User Manual
Snapshot
Use on Dimmer
Outdoor Use
Sound Activated
DMX
Master/Slave
Auto-ranging
Power Supply
Replaceable Fuse
User Serviceable
Duty Cycle

Questions and Answers

  • D
    David RodriguezAug 12, 2025
    What to do if Chauvet LED PAR 38-18B Lighting Equipment does not power up?
    • H
      Heather McintyreAug 12, 2025
      If your Chauvet Lighting Equipment isn't powering on, there are a couple of things you can check: first, ensure that the unit is receiving power from the mains. Second, verify that the power cord is securely connected.
  • B
    Brian ArnoldAug 18, 2025
    Why does the breaker/fuse keep blowing on my Chauvet LED PAR 38-18B Lighting Equipment?
    • K
      Kevin LawrenceAug 19, 2025
      If the breaker or fuse continues to blow, it could be due to excessive load on the circuit. Check the total load placed on the electrical circuit. Alternatively, there might be a short circuit in the electrical wiring, either internal or external, so inspect the wiring for any shorts.
  • D
    Donald GilbertAug 27, 2025
    How to fix Chauvet Lighting Equipment not responding to DMX?
    • J
      James WuAug 27, 2025
      If your Chauvet Lighting Equipment isn't responding to DMX signals, consider the following: * Verify the DMX addressing by checking the Control Panel and unit addressing. * Inspect the DMX cables for any damage. * Check the polarity switch settings on the controller to ensure they are correct. * Ensure all DMX cable connections are secure. * If the issue persists, the DMX input or Main PCB may be faulty and need replacement.
  • L
    Lynn Owens PhDSep 3, 2025
    What to do if Chauvet LED PAR 38-18B Lighting Equipment has loss of signal?
    • K
      Kevin SmithSep 4, 2025
      If you're experiencing signal loss with your Chauvet Lighting Equipment, here are a few things to investigate: * Make sure you are using only DMX compatible cables. * If you suspect bouncing signals, install a terminator. * For long cable runs or low-level signals, install an amplifier after a fixture with a strong signal. * If you have many fixtures, install an optically coupled DMX splitter after unit #32. * Keep DMX cables separated from power cables or black lights to avoid interference.

Chauvet LED PAR 38-18B Specifications

Power IconPower
auto-ranging power supply100~240 VAC, 50/60 Hz
power consumption at 120 VAC22 W (0.4 A) max
power consumption at 230 VAC22 W (0.2 A) max
fuseT 1 A, 250 V
Light Source IconLight Source
led power1 W
led current350 mA
led lifespan50, 000 hrs
Photo Optic IconPhoto Optic
luminance at 1 m4, 000 lux
beam angle16°
field angle32°
Operating Environment IconOperating Environment
maximum ambient temperature104° F
Weight and Dimensions IconWeight and Dimensions
length9.3 in
width8.8 in
height11.4 in
weight3.7 lbs

Related product manuals