FB11 as picture attached
2.2Com port/USB port problem
Fault description:
The receiver cannot make the connection to the PC with the serial cable.
Detection Method &Solution:
1The serial cable has some problem.
If so, please replace another serial cable to have a try.
2Detect the serial FPC flexible circuit board. Separate the receiver to check the
band correctly install or not.
If not, please re-install or replace the FPC flexible PCB.
3The core board chip has fault. When the power supply, the C60 capacitance
voltage should be 5V. If not, please replace the mainboard.