6
7
Operation & Servicing
Switching on
1 Turn the gain controls to the minimum positions.
2 Connect the unit to a mains supply of sufcient power and click the front panel switch(es)
to the ON position. Depending on the internal temperature, the fans may run.
The green Power indicators will illuminate.
The red Clip indicators will illuminate if overdriving is imminent.
WARNING: Keep sound levels down. High levels of sound can damage hearing.
Switching off
Turn the gain control(s) to the minimum position(s). Click the front panel switch(es) to the
OFF position and disconnect from the mains supply.
WARNING: High voltages are present at output terminals for a period after switching off.
Protection systems
Mains power supply failure: When power is restored, the amp will AutoMute forve seconds.
Do not increase gain settings during this period. Note: A500, A700v, Line250 and Line500
do not AutoMute.
Shorted output: The unit can operate indenitely into a shorted output. Normal operation
will resume upon removal of the short circuit.
Low load impedance: Protection is immediate.
Clipping: The affected channel’s red Clip indicator will illuminate shortly before clipping.
A further increase in signal level will activate the SoftClip circuit.
RF, DC or very low frequency signal at output: A self resetting circuit will activate to
protect the load.
Cooling systems: The internal fans react to both high signal level and temperature inside
the unit. If the ambient temperature is high, fan speed will increase even in the absence of
a signal.
Servicing
WARNING: All servicing and internal maintenance must be referred to an authorised Chevin
dealer. Chevin Research accepts no responsibility or liability relating to injury or damages
suffered as a result of misuse or unauthorised tampering with ampliers.
Do not remove any covers or touch any internal parts. Do not allow any objects (e.g.
screwdrivers, cable ends, etc.) to enter the unit.
If the unit of any other electrical equipment in the system becomes wet during operation,
disconnect the power source immediately. Do not touch the amplier. Consult a qualied
engineer.
If there are any signs of mechanical damage, disconnect the power source and consult a
qualied engineer.