Vibration
Fault in atomisers or atomisers of an incorrect type.
Restricted movement of engine speed control.
Engine temperature is too high.
Fan damaged.
Fault in engine mounting or flywheel housing.
The pressure of the lubricating oil is too high
Wrong grade of lubricating oil.
Defective gauge.
The engine temperature is too high
Restriction in air filter/cleaner or induction system.
Fault in atomisers or atomisers of an incorrect type.
Fault in cold start system.
Restriction in exhaust pipe.
Fan damaged.
Too much lubricating oil in sump.
Restriction in air or coolant passages of radiator.
Insufficient coolant in system.
Crankcase pressure
Restriction in breather pipe.
Vacuum pipe leaks or fault in exhauster.
Bad compression
Restriction in air filter/cleaner or induction system.
Incorrect valve tip clearances.
The engine starts and stops
Dirty fuel filter element.
Restriction in air filter/cleaner or induction system.
Air in fuel system.
The engine shuts down after approx. 15 sec.
Bad connection towards oil pressure switch/coolant
temperature switch.