Portable Gasoline Generator Operating Instructions
Common Fault Analysis
Common Fault Analysis
Fault phenomenon
Fault cause
Operation method
The
can not start
generator
no power output
Vibration while operation
Vibration while operation
The emits
black smoke
generator
The emits
blue smoke
generator
The power decreases
No fuel
The oil switch is not
turned on
The oil switch is blocked
No engine oil or the engine
oil level is low
The shutdown switch
is turned off
The spark plug fails
The circuit breaker is
not connected
The plug is poorly
contacted
The choke position
is incorrect
The temperature of the
engine is too low
The fuel oil is contaminated
The air filter is dirty
The load is too high
The engine oil is too much
The engine oil type
is incorrect
The spark plug fails
The valve clearance is
out of limits
Fill the oil tank with gasoline
Turn the oil switch to ON
Clean the oil cup
(refer to page 30)
Add oil
Turn the switch to
the on position""
Clean or replace the spark
plug (refer to page 30)
Turn the circuit breaker to
the on position""
Replace a socket
Move the choke to the
on position during operation""
Let the engine run at empty
load for more than 10 minutes
Replace clean oil
Clean the filter element
of the air filter
Reduce load to the
rated limit
Drain some oil
Choose appropriate engine
oil type(refer to page 17)
Clean or replace the spark
plug (refer to page 30)
Adjust the valve clearance
refer to page 31
()
The environmental requirements of the generator:
Suitable temperature 15 40 .-℃-℃:
%Suitable humidity lower than 95 .:
Suitable altitude under 1,000 meters it should be used with lower
power in districts higher than 1,000 meters. .
(
)
:
If there is no problem with the conditions above please turn to the
nearby dealer or after sales service center for consultancy.
,
-
The generator set can only be loaded to the rated power under the
specified environment conditions If the environment conditions are
inconsistent with the above standards or if the cooling conditions of the
engine and generator set are defective for example when running in
limited areas it is necessary to reduce the power It is also necessary
to reduce the power when the temperature altitude and relative
humidity exceed the standards.
.
,
;,
,.
,
Portable Gasoline Generator Operating Instructions
Common Fault Analysis