25
unit start defrost shall meet one of the following conditions
a. compressor cumulate running time over 30 minutes and it continuous running over 3 minutes, the
temperature of coil pipe of the outdoor units is equal to or less than 15 for one minutes (Tp
2
≤-15℃).
b. compressor cumulate running time over 40 minutes and it continuous running over 3 minutes, the
temperature of coil pipe of the outdoor units is equal to or less than 5 for one minutes (Tp
2
≤-15℃).
c. Air conditioner first power on or it wait over 30 minutes ,the temperature of coil pipe of the outdoor units is
equal to or less than 2 (Tp
2
≤-15℃)
end defrost condition(meet one of follows)
a. the temperature of coil pipe of the outdoor units is more than 15 (Tp
2
≥-15℃).
b. defrost time have fifteen minutes.