EasyManua.ls Logo

Chino KP3000 - Page 36

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E12
Zone 3 *
0: None
R: Communication 1 port (RS232C)
+ 3 external signal inputs
A: Communication 1 port (RS422A)
+ 1 external signal input
S: Communication 1 port (RS485)
+ 2 external signal inputs
B: Communication 2 port (RS232C + RS232C)
+ 1 external signal input
C: Communication 2 port (RS232C + RS422A)
+ 1 external signal input
D: Communication 2 port (RS232C + RS485)
+ 1 external signal input
E: Communication 2 port (RS485 + RS232C)
+ 1 external signal input
F: Communication 2 port (RS485 + RS422A)
+ 1 external signal input
G: Communication 2 port (RS485+RS485)
+ 1 external signal input
9: Heater snapping wire alarm *2
P: External signal input 6 points
M: External signal input 4 points
+ Heater snapping wire alarm *2
T: External signal output 6 points
N: External signal output 4 points
+ Heater snapping wire alarm *2
U: External signal input 8 points
V: External signal input 6 points
+ Heater snapping wire alarm *2
W: External signal output 8 points
X: External signal output 6 points
+ Heater snapping wire alarm *2
Y: External signal input 3 points
+ External signal output 5 points
Z: External signal input 4 points
+ External signal output 4 points
Case color
G: Gray
B: Black
IP54 panel sealing specifications and terminal cover *
0: None
1: Terminal cover exists
2: IP54 panel sealing specifications + No terminal cover
3: IP54 panel sealing specifications
+ Terminal cover exists
Power voltage
A: 100 to 240V (AC)
D: 24V (AC/DC)
* Option
1): It can be selected when control mode (output number 1) is
1, 3, 5, or 6.
2): It can be selected when control mode (output number 1) or
control mode (output number 2) is 1 or 5 (pulse type).
Heater snapping wire alarm cannot overlap with other zones.
When output 1 and output 2 are both pulse type, alarm is judged
output 1 side.
3): It can be selected when zone 2 is 1, 2, 3, or 4.
4): It can be selected when zone 2 is 0, 1, 2, 3, 4, J, K, or L
Note: Common options of zone 1,2,3 are designated priority form
zone 3 ordering [9], [P], [M]
KP3 0 C -
Outputs signal
1: Digital output (RS422A)
2: Analog output (4 to 20mA)
4: Analog output (0 to 10V)
5: Analog output (0 to 1V)
6: Analog output (Others)
7: Digital output (RS485)
Option zone 1 *
0: None
P: External signal input 6 points
T: External signal output 6 points
Option zone 2 *
0: None
P: External signal input 6 points *1
T: External signal output 6 points *1
Option zone 3 *
0: None
R: Communication 1 port (RS232C)
+ External signal input 3 points *2
A: Communication 1 port (RS422A)
+ External signal input 1 point *3
S: Communication 1 port (RS485)
+ External signal input 3 points *2
B: Communication 2 port (RS232C + RS232C)
+ External signal input 1 point *4
C: Communication 2 port (RS232C + RS422A)
+ External signal input 1 point *4
D: Communication 2 port (RS232C + RS485)
+ External signal input 1 point *4
E: Communication 2 port (RS485 + RS232C)
+ External signal input 1 point *4
Model code list

Other manuals for Chino KP3000