Override Box Wiring
MT2309B
7
Wiring to Weigh Bin, Fill System, and Feed Line Motors
M1
WEIGH BIN FILL MOTOR
3/4 HP, 230V, 1 PHASE
25697 SAFETY SWITCH
(SL)
ADDITIONAL CONTACTOR FOR
FEEDER LINE POWER UNITS
REQUIRED IF TOTAL HP IS
GREATER THAN 2 HP. (NOT SUPPLIED)
L1
L2
25694 JUNCTION BOX
ASSEMBLY
123456
M2
L1
L2
HOPPER
FILL MOTOR
1 HP, 230 V
1 PHASE
UPPER HOPPER
LEVEL CONTROL
(S5)
6500 CONTROL UNIT
L1
L2
L1
L2
L1
L2
F. FILL
RELAY
FEED LINE RELAY
W. FILL
RELAY
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
JUMPER TO BE
INSTALLED IN
FIELD
123456789101112
240vac
SUPPLY
GROUND
Figure 7. Wiring to Weigh Bin