Programmable AC Source
61501/61502/61503/61504
User’s Manual

Table of Contents

Questions and Answers

  • M
    Margaret Robinson MDAug 17, 2025
    What to do if Chroma AC Power Distribution shows OVER CURRENT protection (OCP)?
    • A
      Aaron SnyderAug 17, 2025
      If the Chroma AC Power Distribution unit displays an OVER CURRENT protection (OCP) message, it means the output current exceeds the specified limit or the I LIMIT is exceeded. To resolve this, remove the overload or increase the I LIMIT setting.
  • J
    Joshua DelgadoAug 19, 2025
    What to do if Chroma 61502 AC Power Distribution shows OVER POWER protection (OPP)?
    • M
      Mrs. Amanda Walker PhDAug 19, 2025
      If the Chroma AC Power Distribution unit displays an OVER POWER protection (OPP) message, it indicates that the output power is exceeding the specified limits. To fix this, either reduce the power demand or lower the output voltage.
  • B
    bryancarlsonAug 22, 2025
    What to do if Chroma 61502 AC Power Distribution shows OVER TEMP protection (OTP)?
    • T
      Travis RoachAug 22, 2025
      If the Chroma AC Power Distribution unit is showing an OVER TEMP protection (OTP) message, it means that either the ambient temperature is too high, or the airway is obstructed. To solve this: 1. Ensure the unit is operated within a 0 ~ 40°C environment. 2. Check and clear any obstructions in the airway.
  • J
    Jennifer RogersAug 25, 2025
    What to do if Chroma 61502 shows INPUT FAIL protection (UVP)?
    • K
      Kyle WilsonAug 26, 2025
      If the Chroma AC Power Distribution unit displays an INPUT FAIL protection (UVP) message, it means that the AC source line input voltage is either too low or too high. You should measure the input voltage and adjust it if it is outside of the specified range.
  • D
    Dawn WilliamsAug 28, 2025
    What to do if Chroma 61502 shows OUTPUT SHORT protection?
    • J
      Jeffrey JacksonAug 28, 2025
      If the Chroma AC Power Distribution unit displays an OUTPUT SHORT protection message, it indicates either the output is shorted or there's an external current reversal. To resolve this: 1. Remove the short circuit. 2. Remove the load.
  • M
    Mandy FaulknerAug 30, 2025
    What to do if Chroma 61502 shows OUTPUT OVP protection?
    • J
      John PerkinsAug 30, 2025
      If the Chroma AC Power Distribution unit displays an OUTPUT OVP protection message, it indicates that either the remote sense is open, or the output voltage peak is over range. To resolve this: 1. Connect the output to the remote sense terminals. 2. Check the settings of Vac and Vdc on the MAIN PAGE.
  • K
    Kathy FigueroaSep 2, 2025
    Why is the output distorted on my Chroma AC Power Distribution?
    • T
      Tamara ColemanSep 2, 2025
      If the Chroma AC Power Distribution unit displays distorted output, it could be due to two reasons: 1. The AC source output voltage is too low; in this case, program a higher output voltage. 2. The rectified load is too large at high frequency; in this case, reduce the load or lower the output frequency.
  • B
    benjamin70Sep 5, 2025
    What to do if Chroma AC Power Distribution shows INT _ AD protection?
    • A
      Anna FordSep 5, 2025
      If the Chroma AC Power Distribution unit displays an INT _ AD protection message, this could be due to a line input voltage cycle dropout, an instant over current of output, or a damaged AD power stage. To address this: 1. Check the stability of the input voltage. 2. Remove the load. 3. If the protection status cannot be reset, consult the dealer for assistance.
  • D
    David ElliottSep 8, 2025
    What to do if Chroma 61502 shows INT _ DD protection?
    • S
      Shane ColemanSep 8, 2025
      If the Chroma AC Power Distribution unit displays an INT _ DD protection message, this could be due to a line input voltage cycle dropout, an instant over current of output, or a damaged DD power stage. To address this: 1. Check the stability of the input voltage. 2. Remove the load. 3. If the protection status cannot be reset, consult the dealer for assistance.
  • J
    jeffreymooreSep 12, 2025
    How to fix Chroma AC Power Distribution when it cannot control AC source by GPIB?
    • L
      lhoffmanSep 12, 2025
      If the Chroma AC Power Distribution unit cannot be controlled by GPIB, it may be due to an incorrect unit address or a loose GPIB cable. To solve this: 1. Update the address. 2. Check the connection and tighten the screws.

Summary

Installation

Power-on Procedures

Step-by-step guide for powering on and initial self-test.

Local Operation

MAIN PAGE Overview

Understanding the primary display for settings and measurements.

Application Modes

Calibration

Voltage Calibration

Procedure for calibrating output voltage and measurement accuracy.

Current Calibration

Procedure for calibrating output current and measurement accuracy.

Safety and Troubleshooting

Safety Summary and Symbols

Essential safety guidelines and hazard symbol explanations.

Self Test and Problem Solving

Procedures for self-testing and resolving common issues.

Remote Operation

Chroma 61502 Specifications

General IconGeneral
Operating Temperature0°C to 40°C
Output Current16A
Control InterfaceEthernet, RS-232
Crest Factor3
Maximum Current per Phase16A
Circuit Breaker16A per phase