EasyManua.ls Logo

Chroma 66202 - 5.8.2 Instrument Commands; FETCH & MEASURE Sub-system

Default Icon
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using Remote Control
triggers the acquisition of new data before returning data. FETCh returns the
previously acquired data from measurement buffer.
Setting Syntax:
none
Setting Parameters: none
Query Syntax:
FETCh?<PMT>
FETCh?<space><CRD>,<CRD>,<CRD>,…<PMT>
MEASure?
MEASure?<space><CRD>,<CRD>,<CRD>,…<PMT>
Query Parameters: <CRD>,
66201: V, VPK+, VPK-, I, IPK+, IPK-, CFI, W, PF, VA, VAR, FREQ
66202: V, VPK+, VPK-, THDV, I, IPK+, IPK-, IS, CFI, THDI, W, PF, VA,
VAR, ENEG, FREQ
Response Parameters: <NR2>
Example 1:
Query: FETC?<PMT>
Response:
Header on:
66201: :FETCH<space>V<space><NR2>;VPK+<space><NR2>;VPK-<space
><NR2>;I<space><NR2>;IPK+<space><NR2>;IPK-<space><NR2>;
CFI<space><NR2>;W<space><NR2>;PF<space><NR2>;VA<space>
<NR2>;VAR<space><NR2>;FREQ<space><NR2><RMT>
66202: :FETCH<space>V<space><NR2>;VPK+<space><NR2>;VPK-<space
><NR2>;THDV<space><NR2>;I<space><NR2>;IPK+<space><NR2>
;IPK-<space><NR2>;IS<space><NR2>;CFI<space><NR2>;THDI<spa
ce><NR2>;W<space><NR2>;PF<space><NR2>;VA<space><NR2>;
VAR<space><NR2>;ENEG<space><NR2>;FREQ<space><NR2><R
MT>
Header off:
66201:
<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2
>;<NR2>; <NR2>;<NR2><RMT>
66202:
<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2
>;<NR2>; <NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2><RMT>
Separator 0:
66201:
<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2
>,<NR2>,<NR2>,<NR2><RMT>
66201:
<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2
>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2>,<NR2><RMT>
Separator 1:
66201:
<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2
>;<NR2>;<NR2>;<NR2><RMT>
66202:
<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2
>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2>;<NR2><RMT>
5-15

Other manuals for Chroma 66202

Related product manuals