Essential safety guidelines for installation personnel, covering hazards, protective gear, and electrical safety.
Lists and illustrates all accessories supplied with the unit for installation and operation.
Guidelines for selecting optimal indoor and outdoor unit locations, considering clearances and environmental factors.
Details on mounting plate dimensions, fixing, and hole specifications for indoor unit installation.
Step-by-step instructions for installing the indoor unit, including wall hole drilling, pipe connection, and wiring.
Provides mounting dimensions for various outdoor unit models and requirements for fixing bolts.
Specifies required clearances around the outdoor unit for single and parallel installations.
Instructions for connecting electrical wires to the outdoor unit's terminal block and securing the control box.
Steps for securely installing the outdoor unit base, ensuring strength, horizontality, and vibration-proofing.
Guidance on connecting the drain outlet with an extension hose and securing it to the base pan.
Instructions and tools required for performing precise flaring on refrigerant pipes.
Guidelines for connecting refrigerant pipes, including tightening torque and selecting insulation materials.
Details on pipe length limits, additional refrigerant charging, and maximum height differences.
Steps for evacuating air from the refrigerant system using a vacuum pump and manifold gauge.
Methods for checking refrigerant pipe connections for leaks using soapy water or leak detectors.
Diagram and instructions for connecting wires to the indoor unit terminal block, including magnetic ring installation.
Diagram and instructions for connecting wires to the outdoor unit terminal block, including magnetic ring installation.
A comprehensive checklist to verify correct installation before starting trial operation.
Instructions on how to access and use the manual operation mode for testing the unit.
Procedures for conducting a trial run of the air conditioning unit to check its performance.
Safety checks required for areas where flammable refrigerants are used, focusing on ignition risk minimization.
Guidelines for controlled work procedures and ensuring the work area is safe from flammable gases.
Ensuring the technician is aware of potentially flammable atmospheres using appropriate detection equipment.
Precautions regarding fire extinguishing equipment and eliminating ignition sources during work.
Ensuring adequate ventilation in the work area to disperse any released refrigerant safely.
Ensuring electrical components meet specifications and adhering to manufacturer's guidelines.
Requirements for safe refrigerant charging, including equipment checks, cylinder handling, and pressure testing.
Steps for safely recovering refrigerant and decommissioning the equipment, including electrical isolation.
Ensuring equipment is labelled correctly after decommissioning and indicating the presence of flammable refrigerant.
Checking cabling for wear, corrosion, pressure, and adverse environmental effects.
Prohibiting ignition sources when searching for or detecting refrigerant leaks.
Acceptable methods for detecting leaks using electronic detectors or fluids, with safety precautions.
Procedures for removing and evacuating refrigerant from the system, including purging and flushing.
Best practices for safely removing and transferring refrigerants, using appropriate cylinders and equipment.
Compliance with regulations for transporting, marking, and storing units containing flammable refrigerants.