TROUBLESHOOTING
fault messages
MESSAGE
MOTION FAULT Resolver shaft speed equals or exceeds the boundaries of the programmed SPM limits while
the brake solenoid input is at 115VAC (brake off)
A broken resolver to machine shaft coupling or chain.
Excessive clutch slippage or the motion delay is set to short.
An attempt is made to run the machine with the brake solenoid input disconnected.
ANGLE FAULT The resolver cable becomes disconnected.
The line voltage momentarily drops below minimum.
Noise on the line voltage, the brake input, or the resolver input.
The resolver speed exceeds 999spm
BATCH COUNT Although not a fault the Fault relay will de-energize when the strokes count is equal to or
greater than the programmed batch and the programmed top stop angle is exceeded.
9 9