EasyManua.ls Logo

CircuPool Universal UL-25 - Electrical Wiring

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
Bonding:
A lug used for bonding is attached to the bottom of the Universal
Series Control Module. The Control Module must be bonded with an 8
AWG copper wire to the pool bonding system.
Electrolytic Cell and Flow Switch Connections:
The Cell and Flow Switch cables have easy plug-in connectors, which
attach easily to the Control Module. Refer to the diagram below for the
location of these connections.
Wiring to Power Source:
Always double-check the voltage of your power source. Connection to
improper voltage can: a) cause severe damage/harm, or b) cause lights
and screen to power on without system function.
The RJ-Series is shipped from the factory with a 240 VAC configuration.
If 120VAC is needed, move the internal jumpers as shown on page 23. If
unsure, seek professional advice.
POWER CORD
BONDING LUG
FLOW SWITCH
CELL CABLE

Related product manuals