Cirrus Design Section 3
SR20 Emergency Procedures
P/N 13999-004 Info Manual 3-9
Airstart
Engine Airstart
1. Bat Master Switches ..................................................................ON
2. Power Lever .....................................................................½” OPEN
3. Mixture ................................................................ RICH, AS REQ’D
4. Fuel Selector........................................................ SWITCH TANKS
5. Ignition Switch....................................................................... BOTH
6. Fuel Pump ......................................................................... BOOST
7. Alternate Induction Air ...............................................................ON
8. Alt Master Switches .................................................................OFF
9. Starter (Propeller not Windmilling)...................................ENGAGE
10. Power Lever ....................................................... slowly INCREASE
11. Alt Master Switches ...................................................................ON
12. If engine will not start, perform Forced Landing checklist.
Amplification
Switching tanks and turning the fuel pump on will enhance starting if
fuel contamination was the cause of the failure. Leaning the mixture
and then slowly enriching mixture may correct faulty mixture control.
Engine airstarts may be performed during 1g flight anywhere within
the normal operating envelope of the airplane.