VCC-G20X30B Rev. 900-731-31-00
©2012 CIS Corporation. All rights reserved.
11
768H
Internal HD
WEN Output
28H
Internal VD
Video Output
Trigger Input
12H
1H
Pulse Width: 4μs250ms
Exposure Time
Setting Time by (Trigger Pulse Width + 5μs)
(Full Frame)
768H
External HD
WEN Output
28H
External VD
Video Output
Trigger Input
Pulse Width: 4μs250ms
Exposure Time
1H
10μs65ms
Setting Time by (Trigger Pulse Width + 5μs)
(Full Frame)
Fixed & Pulse Width Trigger Shutter Mode (Sync Reset Mode)
After completion of exposure, internal VD signals are reset and the video will be output 12H later.
Internal VD, Composit SYNC, and WEN are output as one-to-one correspondence to the trigger input so that images can
be captured by any of those output signals.
Generally, HD/VD sync singals are unncessary but with external HD signals input, the signals can be synchronized with
internal HD.
Exposure time =
Set value by switch SW1 SW3: 1/60 1/10000s
Set value by trigger pulse width: 9μs 250ms (Actual time = trigger pulse width + 5μs)
Fixed & Pulse Width Trigger Shutter Mode (Sync Non-Reset Mode)
After completion of exposure, with single external VD input, video can be output from that position. The single external
VD shall be input during the period from 10μs 65ms after completion of exposure time.
External VD input, Composite SYNC output, and WEN output are one-to-one correspondence so that images can be
captured with any signals.
Exposure time =
Set value by switch SW1 SW3: 1/60 1/10000s
Set value by trigger pulse width: 9μs 250ms (Actual time = trigger pulse width + 5μs)