Regulatory Compliance and Safety Information for Cisco 7200 Series Routers
78-3419-19
Site Preparation and Safety Information
Power Considerations
AC and DC power supplies, and an optional redundant (second) power supply, are available for most
systems.
Note Refer to your hardware installation guide for AC and DC power specifications and for redundant power
supply availability.
Be careful when connecting systems to the supply circuit so that wiring is not overloaded.
AC Power
The system is designed for connection to TN power systems. A TN power system is a power
distribution system with one point connected directly to earth (ground). The exposed conductive
parts of the installation are connected to that point by protective earth conductors.
Ensure that the plug-socket combination is accessible at all times, because it serves as the main
disconnecting device.
DC Power
Connect DC-input power supplies only to a DC power source that complies with the safety extra-low
voltage (SELV) requirements in the UL60950-1, CAN/CSA-C22.2 No. 60950-1-03, AS/NZS 60950-1
EN/IEC 60825-1, 21 CFR 1040, EN 60950-1, and IEC 60950-1 standards.
Incorporate a readily accessible two-poled disconnect device in the fixed wiring.
Ensure that power is removed from the DC circuit before installing or removing power supplies.
Tape the switch handle of the DC circuit breaker in the off position.
Use only copper conductors to connect to a DC terminal block.
Use approved wiring terminations, such as closed-loop or spade-type with upturned lugs, when
stranded wiring is required. These terminations should be the appropriate size for the wires and
should clamp both the insulation and the conductor.
Ensure that no exposed portion of the DC-input power source wire extends from the terminal block
plug. An exposed wire can conduct a harmful level of electricity.
Redundant Power
If your system includes an optional redundant (second) power supply, connect each of the two power
supplies to different input power sources. Failure to do so makes the system susceptible to total power
failure in the event that one of the power supplies fails.

Table of Contents

Other manuals for Cisco 7200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 7200 Series and is the answer not in the manual?

Cisco 7200 Series Specifications

General IconGeneral
ChassisModular
Product TypeNetwork Router
Form FactorRack-mountable
SoftwareCisco IOS
PerformanceUp to 2 Mpps
ProcessorMIPS RISC
MemoryUp to 64 MB Flash
InterfacesEthernet, Fast Ethernet, Gigabit Ethernet, ATM, Serial
Power SupplyAC or DC power supply options
SlotsUp to 6 slots
DimensionsVaries by model
WeightVaries by model
Model7200 Series

Related product manuals