Chapter 1 Cisco 7200 VXR Product Overview
Physical Description
1-4
Cisco 7200 VXR Installation and Configuration Guide
78-5469-03
AC-input current
rating
5A
4
at 100-240 VAC with the chassis fully configured
AC-input frequency
rating
50/60 Hz
5
AC-input cable 18 AWG
6
three-wire cable, with a three-lead IEC-320 receptacle on the power
supply end, and a country-dependent plug on the power source end
DC-output power 280W maximum (with either a single or dual power supply configuration)
DC-input voltage
rating
–48 VDC
7
nominal in North America
–60 VDC nominal in the European Community
DC-input current
rating
13A at –48 VDC (370W/–48 VDC = 7.7A typical draw)
8A at –60 VDC (370W/–60 VDC = 6.2A typical draw)
DC-input cable In accordance with local and national wiring regulations
Airflow ~80 cfm
8
Temperature 32 to 104 F (0 to 40 C) operating; –4 to 149 F (–20 to 65 C) nonoperating
Humidity 10 to 90% noncondensing
Recommended
minimum software
requirements
Cisco IOS Release 12.0(2)XE2 or later releases of 12.0 XE
Cisco IOS Release 12.0(3)T or later releases of 12.0 T
Compliance CE Marking
Table 1-1 Cisco 7200 VXR Physical Specifications (continued)
Description Specification