Chapter 1 Cisco 7200 VXR Product Overview
Functional Overview
1-66
Cisco 7200 VXR Installation and Configuration Guide
78-5469-03
Reporting Functions
The Cisco 7200 VXR routers display warning messages on the console if chassis
interface-monitored parameters exceed a desired threshold. You can also retrieve
and display environmental status reports with the show environment, show
environment all, show environment last, and show environment table
commands. Parameters are measured and reporting functions are updated every
60 seconds. A brief description of each of these commands follows.
NPE-100 or NPE-200
Chassis inlet 104 F (40 C) 122 F (50 C) —
Chassis outlet 1 109 F (43 C) 127 F (53 C) 136 F (58 C)
Chassis outlet 2 167 F (75 C) 167 F (75 C) —
Chassis outlet 3 122 F (50 C) 140 F (60 C) 149 F (65 C)
NPE-150
Chassis inlet 104 F (40 C) 122 F (50 C) —
Chassis outlet 1 109 F (43 C) 127 F (53 C) 136 F (58 C)
Chassis outlet 2 167 F (75 C) 167 F (75 C) —
Chassis outlet 3 131 F (55 C) 149 F (65 C) 158 F (70 C)
Table 1-23 Typical Power Supply-Monitored DC-Voltage Thresholds
Parameter Low Critical Low Warning High Warning High Critical
+3.45V +3.26V +3.34V +3.55V +3.63V
+5.15V +4.86V +4.99V +5.31V +5.43V
+12.15V +11.39V +11.67 +12.62V +12.91V
–11.95V –9.52V –10.73 –13.16V –14.38V
Table 1-22 Typical Processor-Monitored Temperature Thresholds (continued)
Parameter High Warning High Critical Shutdown