104 Cisco LAN Switching Configuration Handbook
Distribution_1 (config)# vtp domain GO-CATS
Distribution_1 (config)# interface gigabitethernet 1/1
Distribution_1 (config-if)# switchport mode trunk
Distribution_1 (config-if)# switchport trunk encapsulation isl
Distribution_1 (config-if)# end
Distribution_1 (config)# interface gigabitethernet 2/1
Distribution_1 (config-if)# switchport mode trunk
Distribution_1 (config-if)# switchport trunk encapsulation dot1q
Distribution_1 (config-if)# end
Distribution_1# copy running-config startup-config
An example of the configuration for Distribution_2 follows:
Router(config)# vtp pruning
Router(config)# interface gigabitethernet 1/1
Router (config-if)# switchport mode trunk
Router (config-if)# switchport trunk encapsulation isl
Router (config-if)# end
Router (config-if)# copy running-config startup-config
An example of the Layer 2 IOS configuration for Access_1 follows
Access_1 #config t
Access_1 (config)# vtp mode client
Access_1 (config)# interface gigabitethernet 0/1
Access_1 (config-if)# switchport mode trunk
Access_1 (config-if)# switchport trunk encapsulation dot1Q
Access_1 (config-if)# switchport trunk pruning vlan remove 10
Access_1 (config-if)# end
Access_1# copy running-config startup-config
6-5: Private VLANs
Private VLANs allow for additional security between devices in a common subnet.
Private edge VLANs can be configured to prevent connectivity between devices on
access switches.
Private VLANs can be configured on the Catalyst 6000 and Catalyst 4000 series
products.
Within a private VLAN, you can isolate devices to prevent connectivity between
devices within the isolated VLAN.
Within a private VLAN, communities can be created to allow connection between
some devices and to prevent them from communicating with others.
Promiscuous ports are mapped to private VLANs to allow for connectivity to VLANs
outside of this network.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 4948 and is the answer not in the manual?

Cisco Catalyst 4948 Specifications

General IconGeneral
Switching Capacity136 Gbps
Forwarding Rate102 Mpps
Rack Units1U
MAC Address Table Size32, 000 entries
Authentication MethodRADIUS, TACACS+
RAM256 MB
Flash Memory64 MB
Power DeviceInternal power supply
Voltage Required100-240 VAC
Weight16.5 lbs
Operating Humidity10% to 85% non-condensing
Ports48 x 10/100/1000
Power SupplyInternal
Layer SupportLayer 3
Jumbo Frame SupportYes (up to 9216 bytes)
Routing ProtocolRIP, OSPF, EIGRP, BGP
Remote Management ProtocolSNMP, Telnet, SSH
FeaturesVLAN support, QoS
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.1Q, IEEE 802.1p
Operating Temperature32 °F to 104 °F (0 °C to 40 °C)

Related product manuals