This product is suitable for use in environmental air space in accordance with Section 300.22.C of the National
Electrical Code and sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, C22.1. You
should not install the power supply or power injector in air-handling spaces.
Note
The maximum ambient operating temperature range is 40 to 140°F (40 to 60°C).
Note
Hazardous Locations Standards and Marking Strings
The following standards were used for the hazardous locations approvals and certifications:
CSA C22.2 No. 60079-0:19, 4th Ed., Issued 2019-0
CAN/CSA-C22.2 No. 60079-7:16, 2nd Ed., Issued 2016-10
CSA C22.2 No. 213-17, 3rd Ed., Rev. 2019-08-26
EN IEC 60079-0:2018 EN IEC 60079-7: 2015 +A1:2018
EN IEC 60079-7: 2015 +A1:2018
UL 121201, 9th Ed., Rev. 2019-08-26
UL 60079-0 ,7th Ed., Rev. 2020-04-15
UL 60079-7 5th Ed. Rev. 2017-04-21
The following hazardous locations strings are provided on the router:
Class 1, Div 2, Groups A B C D
Class I, Zone 2, AEx ec IIC T4 Gc
UL 21 ATEX 2512X
Ex ec IIC T4 Gc
EMC Information
For EMC and safety information, see the Regulatory Compliance and Safety Information for Cisco IoT Series
Routers document.
Class A Notice for FCC
Modifying the equipment without Ciscos authorization may result in the equipment no longer complying with
FCC requirements for Class A digital devices. In such an event, your right to use the equipment may be limited