Cable distance
Half the
distance
specified by
the IEEE
standard.
Note
Modal bandwidth
(MHz/km)
Core diameter (microns)
110 m
137 m
250 m
275 m
500 m
160 (FDDI)
200 (OM1)
400
500 (OM2)
2000 (OM3)
62.5
62.5
50
50
50
Cable and operating
distance
Table 5: 10-Gb SR Network Module (FPR4K-NM-6X10SR-F)
MaximumTypicalOperating Mode
1.4 dB
1.7 dB
0.9 dB
1.2 dB
Normal
Hardware bypass
Insertion loss
Cable distance
Half the
distance
specified by
the IEEE
standard.
Note
Modal bandwidth
(MHz/km)
Core diameter (microns)
13 m
16.5 m
33 m
41 m
150 m
200 m
160 (FDDI)
200 (OM1)
400
500 (OM2)
2000 (OM3)
4700 (OM4)
62.5
62.5
50
50
50
50
Cable and operating
distance
Table 6: 10-Gb LR Network Module (FPR4K-NM-6X10LR-F)
MaximumTypicalOperating Mode
1.6 dB
1.9 dB
1.2 dB
1.5 dB
Normal
Hardware bypass
Insertion loss