EasyManua.ls Logo

Cisco Nexus 5600 Series - Page 40

Cisco Nexus 5600 Series
480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Show Commands
show ip igmp interface
MCR-36
Cisco Nexus 5600 Series NX-OS Multicast Routing Command Reference
OL-31626-01
Examples This example shows how to display information about IGMP on an interface (if IGMP is not in vPC
mode, the vPC information is not displayed):
switch(config)# show ip igmp interface vlan 5
IGMP Interfaces for VRF "default"
Vlan20, Interface status: protocol-down/link-down/admin-down
IP address: 20.1.1.3, IP subnet: 20.1.1.0/24
Active querier: 0.0.0.0
Membership count: 0
Old Membership count 0
Route-queue depth: 0
IGMP version: 2, host version: 0
IGMP query interval: 125 secs, configured value: 125 secs
IGMP max response time: 10 secs, configured value: 10 secs
IGMP startup query interval: 31 secs, configured value: 31 secs
IGMP startup query count: 2
IGMP last member mrt: 1 secs
IGMP last member query count: 2
IGMP group timeout: 260 secs, configured value: 260 secs
IGMP querier timeout: 255 secs, configured value: 255 secs
IGMP unsolicited report interval: 10 secs
IGMP robustness variable: 2, configured value: 2
IGMP reporting for link-local groups: disabled
IGMP interface enable refcount: 1
IGMP interface immediate leave: disabled
IGMP Report Policy: None
IGMP State Limit: None
IGMP interface statistics:
General (sent/received):
v1-reports: 0/0
v2-queries: 0/0, v2-reports: 0/0, v2-leaves: 0/0
v3-queries: 0/0, v3-reports: 0/0
Errors:
General Queries received with invalid destination address; v2: 0, v3: 0
Checksum errors: 0, Packet length errors: 0
Packets with Local IP as source: 0, Source subnet check failures: 0
Query from non-querier:0
Report version mismatch: 0, Query version mismatch: 0
Unknown IGMP message type: 0
Invalid v1 reports: 0, Invalid v2 reports: 0, Invalid v3 reports: 0
Packets dropped due to router-alert check: 0
Interface PIM DR: No
Interface vPC CFS statistics:
DR queries sent: 0
DR queries rcvd: 0
DR queries fail: 0
DR updates sent: 0
DR updates rcvd: 0
DR updates fail: 0
switch(config)#
This example shows how to display information about IGMP on an interface in a brief format:
switch(config)# show ip igmp interface brief
IGMP Interfaces for VRF "default", count: 1
Interface IP Address IGMP Querier Membership Version
Count
Vlan20 20.1.1.3 0.0.0.0 0 v2
switch(config)#