414
Cisco Nexus 5600 Series NX-OS Multicast Routing Command Reference
OL-31626-01
Chapter Show Commands
show ip netstack mroute
show ip netstack mroute
To show IPv4 multicast routes in the Network Stack cache, use the show ip netstack mroute command.
show ip netstack mroute [vrf vrf-name]
Syntax Description
Defaults None
Command Modes Any command mode
Supported User Roles network-admin
network-operator
vdc-admin
vdc-operator
Command History
Usage Guidelines This command does not require a license.
Examples This example shows how to display multicast routes in the Network Stack cache:
switch(config)# show ip netstack mroute
(0.0.0.0/0, 225.1.1.1/32)
Software switched packets: 1, bytes: 84
(4.1.1.2/32, 225.1.1.1/32), data-created
Software switched packets: 2, bytes: 168
(0.0.0.0/0, 225.1.1.2/32)
Software switched packets: 0, bytes: 0
(4.1.1.2/32, 225.1.1.2/32), data-created
Software switched packets: 5, bytes: 420
(0.0.0.0/0, 225.1.1.3/32)
Software switched packets: 0, bytes: 0
(4.1.1.2/32, 225.1.1.3/32), data-created
Software switched packets: 2, bytes: 168
(0.0.0.0/0, 225.1.1.4/32)
Software switched packets: 0, bytes: 0
(4.1.1.2/32, 225.1.1.4/32), data-created
Software switched packets: 2, bytes: 168
(0.0.0.0/0, 225.1.1.5/32)
Software switched packets: 0, bytes: 0
(4.1.1.2/32, 225.1.1.5/32), data-created
vrf vrf-name (Optional) Specifies the VRF name. The name can be a maximum of 32
alphanumeric characters and is case sensitive.
Release Modification
This command was introduced.