EasyManua.ls Logo

Cisco ONS 15310-MA - 2.7.147 LPKTERMINAL (CE100 T, CEMR); Clear the LPBKTERMINAL (CE100 T, CEMR) Condition; 2.7.148 LPBKTERMINAL (E1, DS3); Clear the LPBKTERMINAL (E1, DS3) Condition

Cisco ONS 15310-MA
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-104
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
78-18663-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.147 LPKTERMINAL (CE100T, CEMR)
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Objects: CE100T, CEMR
A Loopback Terminal condition on a CE-Series port occurs when a software terminal loopback is active
for a port on the card.
For information about troubleshooting optical circuits with loopbacks, refer to the “1.1 Network
Troubleshooting Tests” section on page 1-2.
Clear the LPBKTERMINAL (CE100T, CEMR) Condition
Step 1 Complete the “Clear an Ethernet Card Loopback Circuit” procedure on page 2-156.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.148 LPBKTERMINAL (E1, DS3)
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Objects: E1, DS3
A Loopback Terminal condition for a E1 or DS-3 signal occurs when a software terminal (inward)
loopback is active for a E1 or DS3 port on a 15310-MA SDH CTX, E1-21/DS3-E3-3, or
E1-63/DS3-E3-3 card. E1 and DS-3 terminal loopbacks do not typically return an AIS signal.
For information about troubleshooting optical circuits with loopbacks, refer to the “1.2 Identify Points
of Failure on an Electrical Circuit Path” section on page 1-4. Facility loopbacks are described in the
“1.1 Network Troubleshooting Tests” section on page 1-2.
Clear the LPBKTERMINAL (E1, DS3) Condition
Step 1 Complete the “Clear a DS-3 or E1 Port Loopback Circuit” procedure on page 2-155.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).

Table of Contents