EasyManua.ls Logo

Citizen iDP-3550 - Page 63

Citizen iDP-3550
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ESC BEL n1 n2
[Function] Setting the external device drive pulse width
[Code] <1B>H <07>H n1 n2
[Range] 1 n1 127 1 n2 127
[Outline] This command sets the power-on time to drive an external device (such as cash drawer).
Power-on time = n1 × 10 (ms)
Delay time = n2 × 10 (ms)
To actually drive the drawer, use the BEL and FS commands.
[Default] n1 = n2 = 20
BEL
[Function] Driving command A for drawer-1
[Code] <07>H
[Outline] This command drives the drawer connector No. 2 pin under the condition set with the ESC
BEL n1 n2 command. This command is executed in order of entry into the input buffer.

Table of Contents

Other manuals for Citizen iDP-3550

Related product manuals