Operator's Manual
Transesophageal Probe Reprocessor
Manufactured by:
CIVCOMedical Solutions
102 First Street South
Kalona, IA 52247 USA
319.248.6757 / 800.445.6741
WWW.CIVCO.COM
Copyright © 2020 All Rights Reserved.
ASTRA TEE and Glute-Out are registered trademarks of CIVCO Medical Solutions.
All other trademarks are property of their respective owners.
Printed in the USA.

Table of Contents

Questions and Answers

  • J
    jared93Aug 3, 2025
    How to fix Civco Astra Tee Medical Equipment when it will not turn on or has no display?
    • K
      Kimberly ShafferAug 4, 2025
      If your Civco Medical Equipment device isn't turning on or the display is blank, here's what to check: 1. **Power Connection**: Ensure the device is properly plugged into a functioning GFI outlet. 2. **Power Switch**: Make sure the power switch is in the 'on' position. 3. **Power Cord**: Verify that the power cord is securely connected to both the device and the wall. 4. **Wall Receptacle**: Confirm that the wall outlet has power. 5. **GFCI**: Reset the GFCI if it has tripped. 6. **Fuse**: Inspect the fuse and replace it if it's blown.
  • E
    elliottalvinAug 14, 2025
    Why does Civco Astra Tee display 'Insert Probe' when the probe is already in place?
    • L
      lharrisonAug 14, 2025
      If your Civco Medical Equipment displays 'Insert Probe' even when a probe is connected, the issue might be due to improper placement of the probe cord or a cable sensor failure. Check the probe cord to ensure it is correctly and firmly placed.
  • T
    tammywilsonAug 25, 2025
    What to do if there is water leakage around Civco Astra Tee Medical Equipment?
    • S
      Stephanie BergerAug 25, 2025
      If you notice water leaking around your Civco Medical Equipment, take these steps: * Immediately turn off the water supply to prevent further leakage. * Check the quick disconnect on the side of the device to ensure it's properly seated. A disconnected or broken drain line could be the culprit. * If the issue persists, it may indicate an internal plumbing failure.

Summary

ASTRA TEE System Overview

Instruction Manual

Provides essential information for setup, maintenance, and safe operation of the ASTRA TEE device.

Overview of ASTRA Models

Describes the three unique ASTRA models and their data tracking capabilities.

Warnings & Cautions

Highlights critical safety warnings, cautions, and potential hazards associated with device use.

Emergency Shut Down Procedure

Details the steps for safely shutting down the ASTRA TEE system in an emergency situation.

Symbols

Explains the meaning of various symbols used on the device and in the manual for clarity.

Labels on the Device

Identifies and explains the labels found on the ASTRA TEE unit for user reference.

Intended Use

Specifies the intended purpose of the ASTRA TEE automated reprocessor for high-level disinfection.

User Qualifications;Safety

Outlines the necessary qualifications, training, and safety precautions for operators.

Device Overview

Provides a visual guide to the components and parts of the ASTRA TEE system.

Operating Instructions

Disinfection Process Overview

Outlines the general workflow for reprocessing probes using the ASTRA TEE system.

Preparing the System

Details the essential steps and checks required before operating the ASTRA TEE system.

Loading Disinfection Consumables

Provides instructions for loading test strip bottles for ASTRA ULTRA models.

Replacing HLD Bottle

Explains when and how to replace the High-Level Disinfectant (HLD) bottle.

Routine Operation of the System

Guides the user through the standard procedure for running disinfection cycles.

Retrieving Cycle History

Describes how to access and download cycle history data from the system.

Downloading and Erasing Cycle History

Details the process for downloading and clearing cycle logs from the ASTRA TEE.

Routine Maintenance

Maintenance and Inspection

Outlines the minimal routine maintenance and inspection requirements for the ASTRA TEE.

Daily Check; Prior to Operation

Specifies the daily checks and cleaning procedures before operating the device.

Six Months Maintenance

Covers scheduled maintenance tasks including water filter replacement, air filter replacement, and WILD cycle disinfection.

User Configurable Settings

Setting Date & Time

Instructions on how to set the system's date, time, and local time zone.

Changing High-Level Disinfectant Type

Guides the user on how to change the High-Level Disinfectant (HLD) setting.

Service and Warranty

Warranty Information

Provides details on the ASTRA TEE product warranty coverage and terms.

Technical Support;Service

Lists contact information for technical support and service inquiries.

Troubleshooting Guide

ASTRA System Error Codes

Site Requirements & Specifications

Approved Probes

EMC Compliance Information

Software Licensing

Civco Astra Tee Series Specifications