18
AX4000G Series
Dimensions
AX4000G
Actuator
Dimensions
AX4150G AX4150G-EB
With electromagnetic brake
Refer to the left drawing for other options.
0.06
A
0.06
B
A
B
P
.
C
.
D
.
2
5
5
Rotational section
(including hollow
section)
280±3
(12.5)
270
160h7
220h7
36.5
12.5
4-M10 depth 20 (straight)
6-M8 depth 16 (straight)
For dial plate mounting
P
.
C
.
D
.
2
5
5
Rotational section
(including hollow section)
280±3
(12.5)
270
160h7
220h7
36.5
Electromagnetic brake lead wire
300 from outlet
3-M8 (straight)
Electromagnetic brake for manual release
4-M10 depth 20 (straight)
P.C.D.260
118
58
Electromagnetic brake
(protection element attached)
29
81.5
6-M8 depth 16 (straight)
For dial plate mounting
240
280
240
280
P
.C
.D
.1
0
0
8H7 depth 10 (option)
127.5
85
C15
4- 12
Mounting base (option)
P
.
C
.
D
.
2
6
0
130
10H7 depth 12 (option)
Not available if the option base is installed.
3-M8 depth 16 (straight)
For option electromagnetic brake
mounting
15
P
.
C
.
D
.
1
9
0
4-M8 depth 16 (straight)
For option electromagnetic brake mounting
41
41
10˚
104
145
104
145
12.5
183
CAUTION :
When using a flexible cable, fix the end of
the cable sheath.
Standard cable length 4 m
47.5
168
6.5
116
26
(11)
170
80
Cable bending range
(The bending
range downward is 60.)
4
5
˚
4
5
˚
10˚
P.C.D.181