40
AX4000
Series
Dimensions
AX4000
Actuator
Dimensions
AX4150 AX4150-EB
With electromagnetic brake
Refer to the left drawing for other options.
4
5
˚
Electromagnetic brake
300 from lead wire outlet
P
.
C
.
D
.
2
6
0
1
0
˚
B
A
130
0.06
B
0.06
A
127.5
For dial plate mounting
Cable bending range
(Cable bending range
downward is 60.)
6-M8 depth 16 (straight)
8H7 depth 10 (option)
P
.
C
.
D
.
2
5
5
240
280
4- 12
Mounting base (option)
C
1
5
240
280
80
CAUTION :
When using flexible cable,
fix the end of cable sheath.
16 27
Standard cable length 4 m
(12.5)
220h7
160h7
270
280±3
85
15
12.5
170
36.5
41 104
145
4
5
˚
10H7 depth 12 (option)
Not available if the option base is installed.
4-M10 depth 20 (straight)
For dial plate mounting
6-M8 depth 16 (straight)
P
.
C
.
D
.
2
5
5
Standard cable length 4 m
(including hollow section)
(12.5)
36.5
220h7
160h7
118
270
12.5
280±3
Rotational section
58
29
18381.5
41 104
Electromagnetic brake
(protection element attached)
145
(including hollow section)
Rotational section
4-M10 depth 20 (straight)
P
.
C
.
D
.
1
0
0
P
.
C
.
D
.
1
9
0
3-M8 depth 16 (straight)
For option electromagnetic brake
mounting
P
.
C
.
D
.
2
6
0
4-M8 depth 16 (straight)
For option electromagnetic brake mounting
3-M8 (straight)
Electromagnetic brake
for manual release
1
0
˚
P. C .D. 181