58
Cable bending radius
Standard cable
Resolver
cable
Resolver
cable
Resolver
cable
Resolver
cable
Resolver
cable
Motor cable
Flexible cable
60mm 60mm
100mm 110mm
Motor cable
50mm 60mm
90mm 90mm
Motor cable
60mm
90mm
Motor cable
50mm 60mm
100mm 110mm
Motor cable
60mm 100mm
100mm 110mm
Safety precautions
Use an actuator, driver, and cable with the same serial No.
Contact CKD if the cable is damaged or broken, or if the cable
length must be changed.
When connecting the motor cable and driver, check that the
cable's mark tubes and driver's indications are correct.
Attach a noise filter for the motor cable on the motor cable
near the driver if the cable is longer than 6 m.
Use the optional flexible cable in applications where the cable
is bent repeatedly. When using the AX2000 or AX4000 series
flexible cable, fix the cable sheath near the actuator
connector.
When connecting the cable, firmly insert the connector to the
back. Firmly tighten the connector's set screws and fixing
screws.
Do not modify the cable by cutting or extending it. Failure to
observe this could result in faults or malfunction.
When using a CE-compatible part (option), use an FG clamp,
etc., for the cable shield on both the driver and actuator
cases, and ground to the cabinet.
Refer to the cable length in How to order on cable length L.
Clamp for FG