71
AX-OPX
Series
Connections
Transmission I/F connector (for installing on GS and S)
* Refer to the following transmission I/F connector for details on connecting communication cables.
* The connector orientation is reversed when installing on the GH or H driver.
PLC
Noise filter
Resolver cable (standard 4m)
Actuator cable
(standard 4m)
Direct drive actuator
RS-232C
200 VAC
three phase
FG
Interactive terminal
No. 3 class
ground and above
ABSODEX
DRIVER S TYPE
G1
CN2
CN1
N3
BK
ABSODEX
POWER
POWER
L1
L2
MON
3AC200V
V
-230V
W
L3
U
G2
50/60Hz
0V
24 VDC
Slave unit power
Power for AX driver
0V
24 VDC
BK
Communication
device
Serial
transmission
communication
line
CN3
S type driver
*
FG
SLD (bare)
DG (yellow)
DB (white)
DA (blue)
V + (red)
CAN H (white)
SHIELD (no color)
CAN L (blue)
V- (black)
AX-OPX-7G (CC-Link) AX-OPX-7D (DeviceNet)