PROXIMA STX
Ice-Cream Cabinet
ENGLISH
23
Change parameters values
Enter programming mode as described above:
1. Select the parameter you want to change with or buttons.
2. Press SET button to visualize the value of the selected parameter.
3. Change its value with or buttons and push SET button to confirm the choice.
The value will flash three times and the display will show the following parameter in the
list.
EXIT
: Push together SET+ on time or wait 30 sec without pressing any key.
WARNING:
the changed new value is memorized also exiting programming mode without
pressing set button.
Keyboard lock
1. Press and hold and keys for some seconds, until the message “POF” will
appear and flash on display.
2. At this point the keyboard is blocked and only setpoint and maximum / minimum
temperatures visualization are available.
3. In order to unlock keyboard press and hold and button for some seconds until
message “Pon” will appear and flash.
Stand-By Function
1. Pressing
ON/OFF
key, “
OFF”
will be displayed.
2. When
OFF
is displayed the machine enters the “Stand-by” mode and all loads and
regulation are disabled. Press again
ON/OFF
button to exit the Stand-by mode.
Note:
During Stand-by mode the light switch is active.
Visualize probe value
1. Enter in level 1 Programming menu.
2. Use and until parameter “prd” appears on display.
3. Press SET key. Then use and for desired probe label.
4. Press SET key for visualize probe value. Press SET key again in order to exit and return
on label visualization.