Replace with a fuse of the same amperage.
If
the fuse blows again, consult your store of
purchase.
Incorrect wiring.
Consult your store of purchase.
1.
Turn
the unit off.
2.
Remove all wires attached to the power
antenna lead. Check each wire for a possible
short to ground using
an
ohm meter.
3.
Turn
the unit back on.
4.
Reconnect each amplifier remote wire to
the power antenna lead one by one.
If
the amplifiers turn off before all wires are
attached, use
an
external relay to provide
remote-on
voltage
(excessive
current
required).
Power antenna lead
is
shorted to ground or
excessive
cu
rrent is
required for remote-on
the amplifiers or power
antenna.
No sound output when
operating the unit with
amplifiers or power
antenna attached.
(ij
G3
c:
(J)
C't-
-1
+--
----I
Nothing happens when
button are pressed.
Display
is
not accurate.
The microprocessor has
malfunctioned due to
noise, etc.
Turn off the power, then press the
[OPEN]
button and remove the
DCP.
Press the reset button for about 2 seconds
with a thin rod.
DCP or main unit
connectors are dirty.
Wipe the dirt off with a soft cloth moistened
with cleaning alcohol.
No sound heard.
The speaker protection
circuit
is
operating.
1.
Turn down sound volume. Function can
also be restored by turning the power off
and
on
again. (Speaker volume
is
reduced
automatically when the speaker protection
circuit operates).
2.
If the sound is muted again, consult our
service department.
26 DXZ365MP