Jump Starting
5.
(Continued)
b.
Connect
one end of the
second cable
to the
grounded negative
"
-
"
(Black)
terminal
of the
good (charged) battery.
c.
Connect
the
other
end of the
second jumper cable
to a
solid,
sta-
tionary, metallic point
on the
engine
of the
truck with
the
discharg-
ed
battery
but at a
point away from
the
battery.
At
least [450
mm] 18
inches from
the
battery
if
possible.
Do not
connect
it to
pulleys,
fans,
or
other parts that move. Take care
not to
touch
hot
manifolds
which
can
cause
severe
burns.
6.
Start
the
engine
on the
truck with
the
good (charged) battery
and run
the
engine
at a
moderate speed.
7.
Start
the
engine
of the
truck that
has
the
discharged battery.
8.
Remove
the
jumper cables
by
revers-
ing the
above sequence exactly.
Start
by
removing
the
last cable
first; that
is,
remove
the
jumper
cable from
the
truck with
the
discharged battery
as the
first step.