EasyManua.ls Logo

Clarke C18H - AIR FILTER SERVICE INSTRUCTIONS

Clarke C18H
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
NOTE: Do not attempt this while engine is running.
NOTE: Do not over oil the reusable element
Engine model
Air filter
restriction limit
(inches of water)
C18H0-UFAD12
25
C18H0-UFAD12-D
C18H0-UFAD22
C18H0-UFAD22-D
C18H0-UFAD32
C18H0-UFAD32-D
C18H0-UFAD42
C18H0-UFAD42-D
C18H0-FMAD12-S
C18H0-FMAD12-DS
C18H0-FMAD22-S
C18H0-FMAD22-DS
C18H0-FMAD32-S
C18H0-FMAD32-DS
C18H0-FMAD42-S
C18H0-FMAD42-DS
Figure #14
Note: Intake Air Shutoff Valve - Engine may
include an intake air shutoff valve as an optional
feature that is activated by an overspeed event and
provides a positive shutoff of combustion air to the
engine. The optional air intake shutoff valve has
not been evaluated by UL as part of a UL Listed
fire pump driver.
3.2.4 Crankcase Ventilation
Vapors that form within the engine are removed from
the crankcase and gear train compartment by a
continuous, pressurized ventilation system. A slight
pressure is maintained within the engine crankcase
compartment. Vapors are expelled through a vent pipe
attached to the rocker cover. Ref. Figure #15. Contact
Clarke for an optional breather kit if vapors accumulate
in your pump room.

Table of Contents

Related product manuals