4
ELECTRICAL CONNECTIONS
Connect the mains lead to a suitable 110 Volt (50Hz) electrical supply through
an approved plug or a suitably fused isolator switch, or to a suitable portable
110 volt transformer.
We recommend that this pump is fitted with a Residual Current Device (RCD).
If the pump is to be connected to an outdoor electrical supply, ensure both
the plug and the socket are of a British Standard approved waterproo
f design.
The wires in the mains lead are coloured according to with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the flexible power cable of this appliance may not
correspond with the coloured markings identifying terminals in your plug
proceed as follows:
Connect GREEN & YELLOW wire to the terminal marked with a letter “E” or
Earth symbol ’or coloured GREEN or GREEN & YELLOW.
Connect BROWN wire to terminal marked with a letter “L” or coloured RED
Connect BLUE wire to terminal marked with “N” or coloured BLACK
IMPORTANT: If you are in any doubt regarding electrical installation, you should
consult a qualified electrician.
PUMP PERFORMANCE DATA
WARNING: THIS APPLIANCE MUST BE EARTHED