TROUBLE SHOOTING
Main power fuse is blown.
Recovery tank switch is stuck
Examine switch replace if necessary.
Faulty connection at Hi-Temp
shut-down
Check and secure connection at both
sensor and harness
Front or rear belts broken.
See authorized Cleanco service center
Water supply is turned off
Turn the water supply on or up. Check
or the float valve is stuck or
for kinks in the water supply hose.
Examine the float valve and adjust
Water pump inlet supply line is
Examine the water inlet filter inside the
water box. Remove accumulated
debris and replace if required. Check
for suction leaks and loose clamps or
fittings. Tighten any loose fittings or
clamps. Replace any ruptured hose(s).
Pressure regulator o-rings are
Lubricate o-rings, using o-ring lubricant.
Pressure regulator has worn
Check o-rings. If necessary, replace.
Pressure regulator is dirty,
Clean or repair regulator. Adjust to
stuck open, or improperly
working pressure. Lubricate o-rings,
Low pump volume. (Measure
Examine the check valves, plunger
the amount of water being
cups, and cylinder head on the water
returned to the water box from
pump. Repair, whenever required
the pressure regulator. It
(refer to the water pump service
should fill a gallon container
Orifice (spray nozzle) in the
Replace nozzle or change nozzle size.
defective, or wrong size.
Debris clogging water lines or
Clean or replace as needed.
Re-tension or replace as needed.
Manually prime water pump.