SAFETY FEATURES
Automatic Defrosting
To ensure the unit operates and performs as
stated, the unit has been designed with an
Automatic defrost function as frost can be
produced on the surface of the evaporator in
low temperatures.
When the temperature sensor detects the room
temperature has dropped to 16°C or lower,
the Auto Defrost function will start and the
DEFROST symbol will be displayed on the
LCD screen. The unit compressor will run for
25 minutes on dehumidification mode and
then the fan will run at high speed in 7 minute
cycles to defrost the unit.
NOTE
The dehumidification symbol
will disappear.
Protection Of Extremely Low
& High Temperature
Unit is built with a room temperature sensor
that will automatically shut off the unit when
the ambient temperature is either less than
or equal to 0°C or greater than or equal to
40°C. When sensor is activated there will be a
continuous warning beeper which will beep 3
long and 2 short beeps and the corresponding
temperature (either 0°C or 40°C) will be
displayed on LCD screen.
NOTE
Unit will not be operable when sensor is
activated, to restart unit, unplug unit and
restart again.
NOTE
If unit is shut off due to protection of extremely
low & high temperatures, the unit memory
function will not operate, unit will reset at
default setting.
Failure of Humidity & Temperature Sensor
When the connection wire between the
humidity and temperature sensor is
disconnected, the humidity icon will blink
and 0°C and 0% RH will display on LCD
screen. Unit will switch into continuous
dehumidifying mode.
If the temperature evaporator sensor becomes
open circuit or short circuit the DEFROST light
will start blinking.
Unit will operate in a humidifying and
defrosting mode, dehumidifying for 20
minutes and then defrosting for 5 minutes.
NOTE
If the temperature sensor malfunctions, the
unit will continue to work but at a lower
efficiency.
Compressor Protection
If the unit malfunctions during the operation
of the unit and the compressor fails, the
compressor will switch off. Wait a minimum of
three minutes to reoperate unit.
Memory Function
If the power is cut off during the operation
of the appliance, the unit will memorise the
working mode automatically.
Once power is restored to the unit, the
appliance will restart and continue working at
the last set working mode.
NOTE
If the ON/OFF timer has been set and
activated, the unit will restart at default
operating mode, not at previous set mode.
NOTE
If power supply is cut off due to one of the
safety features being activated, the unit will not
restart at previous set mode but at the default
mode.