14
Center, it will automatically enter
Listen-In Half Duplex for 1-10 minutes
(set by Command 46) allowing the
Monitoring Center Personnel to listen in
to what is happening on the other side.
) When (2) is selected, after CTC-1052
has made a report to the Monitoring
Center, it will immediately enter a Two-
way Full-duplex Communication
mode for 1-10 minutes (set by
Command 46), that gives the user the
ability to speak directly with the
Monitoring Center Personnel.
) If either Scancom or Tunstall reporting
format is selected, CTC-1052 will
ignore Command #45
selections. It will
always open a Two-way voice for
Follow-On choice.
Command 46
Follow-On Mode & Two-Way Period
z This command is used to program the
allowable time duration for Follow-On
mode choice (Commend #45) & Two-way
voice communication period (Speech
mode). It can be set from (01) (1 minute) -
(10) (10 minutes).
Function Selection Result
(01) 1 MINUTE
(02) 2 MINUTES
(03)-(10) 3-10 MINUTES
z Factory default is set as (05) 5 minutes.
The allowable time duration for either Wait
Command, Two-way, Listen-In Only or
Two-way voice comminucation in
Speech mode is two mins. During the 2-
min period, CTC-1052 will emit two beeps
via the telephone handset to alert the call
recipient the remaining time of 20 & 10
secs. Pressing assigned DTMF key can
extend another 1-10 minute(s).
Command 47
Off-Set Time
z After the Control Panel‘s power is supplied,
the time of the Check-in Report starts
calculating.
z According to the setting of Off-Set Time,
the Control Panel will send Check-in
Report once, and then send report
according to the setting of Command 43
- Test call.
Function
Selection
Result
(1) 1 Hour
(2) 2 Hour
(3) 3 Hour
(4)
4 Hour
(5)
8 Hour
(6) 12Hour
z Factory default is set as (1) 1 Hour. When
the Off-Set Time is reset in programming
Mode, the time of the Off-Set period will
recalculate.
z Off-Set time Report will be sent only once,
and then the Control Panel sends Check-in
Report according to setting of period test
call, unless the Control Panel restarts or
the Off-Set time is reset.
<
<
N
N
O
O
T
T
E
E
>
>
) Whenever programming mode is
accessed, CTC-1052 will reset the
Off-Set timer.
Command 49
Supervision
This function is not available for the digital
Scancom reporting method.
z This option is used to enable system
Supervision function. Once enabled, CTC-
1052 will be able to receive the check-in
signals from Wrist Pendants (WTR-) to
indicate their proper functioning.
Function
Selection
Result
(0) Disable
(1) 4 Days
(2) 5 Days